Heatrex
425 Hanley Industrail Court, St. Louis, MO 63144
Toll Free: (800) 394-6589 • Phone: (814) 724-1800 • Fax: (314) 644-5332
E-mail: sales@heatrex.com
• Website:
www.heatrex.com
|
|
|
|
Item # HX-934U00500B, 934 Series Economical Wall Heater
|
|
|
|
The 934 Series wall heater is designed for recessed mounting into shallow 2-inch by 3-inch stud walls. It provides heat in a quiet, efficient manner. Single units can heat small areas and multiple heaters can be used in large or odd shaped rooms.
- Mounting Options : Units can be surface or recessed mounted, vertically or horizontally, in one of four positions. A tapered recess box assures a tight fit when mounted into the wall.
All models listed are single-phase.
|
|
|
|
|
Power
|
|
500 W
|
|
Voltage Rating
|
|
120 V
|
|
Total Amps1
|
|
4.6 A
|
|
Airflow
|
|
40 CFM
|
|
Approx. Air Temperature Rise
|
|
40 ºF 22 ºC
|
|
Weight
|
|
9 lb 4 kg
|
|
Color Options
|
|
A - Almond W - White
|
|
Factory Built-in Options
|
|
D3 - Disconnect Switch, 277 V, Double-pole, 20 Amp T1 - Tamperproof Thermostat Single-pole, 25 Amp T2 - Tamperproof Thermostat, Double-pole 25 Amp with off position T5 - Adjustable Thermostat, Singlepole 25 Amp T6 - Adjustable Thermostat, Double-pole 25 Amp with off position
|
|
Field-Installed Options
|
|
934-124647 - Surface Mounting Box 934-124648 - Adjustable Thermostat Kit, Single-pole, 25 Amp 934-124649 - Tamperproof Thermostat Kit, Single-pole, 25 Amp 934-124650 - Adjustable Thermostat Kit, Double-pole, 25 Amp with off position 934-124651 - Tamperproof Thermostat Kit, Double-pole, 25 Amp with off position
|
|
1 Total Amps = Heating element amps and motor amps.
|
|
|
|
|
- Heating Elements - Steel finned tubular elements.
- Outlet Grille -The louvered front grille is made from 20-gauge steel with rounded corners. The grille is finished with an epoxy-polyester powder paint in white or almond.
- Built-in Controls - Automatic reset thermal cutout.
- Fan Motor - Quiet, permanently lubricated axial fan operates at 38 dBA at 40 CFM for models up to 1000 W and 41.3 dBA at 80 CFM for all models rated above 1000 W.
- Installation Requirements - The air outlet should be installed a minimum of ten inches above vinyl floors.
|
|
|
|
- Breezeways
- Entryways
- Restrooms
- Small Offices
- Storage Rooms
|
|
|
|
|
|
|
|
|
|
|
|
|
|