Heatrex
425 Hanley Industrail Court, St. Louis, MO 63144
Toll Free: (800) 394-6589 • Phone: (814) 724-1800 • Fax: (314) 644-5332
E-mail: sales@heatrex.com
• Website:
www.heatrex.com
|
|
|
|
Item # HX-233-FA-0106K, 233 Series Explosion-Proof Unit Heater
|
|
|
|
Heatrex's 233 Series Exp explosion-proof unit heater is designed with both safety and versatility in mind. Unique 233 Series features include :- Industry's Lowest Ignition Temperature Code Rating : T3C, 320°F (160°C)
- Dual Over temperature Protection: With both automatic and manual reset over temperature cutouts for additional safety.
- Nontoxic Propylene Glycol Heat Transfer Fluid
- Low 70 PSIG Relief Valve Setting : This assures that in an emergency, the initial escaping vapor temperature remains below the 320°F (160°C) ignition temperature.
- Corrosive Resistant Options : Heatrex offers three constructions suitable for most applications. Standard construction for use in dry non-corrosive areas includes : Welded steel heat exchanger; powder-coated cabinet; epoxy-coated motor. A 316 stainless steel construction suitable for Waste Water Treatment Plants includes : 316 stainless steel heat exchanger, headers and tubes with aluminum fins; stainless steel cabinet; corrosive resistance hardware; epoxy-coated motor. Third construction is suitable for use in Chemical Plants where chlorides are present and includes : Heresite® coated heat exchanger, cabinet, fan blade; corrosive resistance hardware; epoxy-coated motor.
|
|
|
|
|
|
|
- Heat Exchanger - Efficient liquid-to-air design utilizes an all welded steel headers and finned tube construction with spiral wound aluminum fins. Industrial grade Heatrex heating elements are immersed in a nontoxic, inhibited, propylene glycol heat transfer fluid that provides freeze protection down to -49°F (-45°C). The heat exchanger is hydrostatically tested at 350 psig. A pressure relief valve provides excess pressure protection and is set at 70 psig.
- Fan Motor Assembly - Consists of an explosion-proof motor fitted with an aluminum fan blade. The motor has double-shielded, permanently lubricated ball bearings and automatic reset line breaking thermal overload protection. Motors furnished on standard units operate at line voltage and are prewired to the control enclosure so separate field wiring to the motor is not required. The standard motor is rated for Class I, Groups C and D, Class II, Groups F and G. The minimum operating temperature is -14°F (-25°C) and the minimum storage temperature is -49°F (-45°C).
- Cabinet/Louvers - Industrial grade, corrosion resistant construction fabricated from powder coated 14-gauge galvanized steel. The adjustable louvers have minimum opening safety stops.
- Controls - Factory mounted on the unit heater. Standard built-in controls include automatic and manual reset over temperature cutouts, controlling magnetic contactor, 24-volt control circuit transformer and incoming power terminal blocks housed in a NEMA 7, 9 cast aluminum enclosure.
|
|
|
|
- Aircraft Hangars/Service Areas
- Chemical Storage/Handling Areas
- Coal Preparation Plants
- Compressor Stations
- Grain Elevators
- Oil Refineries and Rigs
- Paint Storage Areas
- Petrochemical Plants
- Sewage Pump Stations/Treatment Plants
- Spray Booths
|
|
|
|
Class I, Divisions 1 and 2, Groups C and D Class II, Divisions 1 and 2, Groups E, F and G Class I, Zones 1 and 2, Group IIB Temperature Code T3C, 320°F (160°C)
|
|
|
|
|
|
|
|
|
|
|
|
|
|